Home » Incinerator

Incinerator

1. SINGLE BURNER PORTABLE INCENERATOR

Portable IncineratorSpecification :

Type of Waste : Laboratory Waste / Medical Waste
Incinerator Capacity : 0.01 m3/hour
Incinerator Type : Single Chamber
Operation Time : 8 hour/day
Chamber Volume : – 1st Chamber 0.024 m³
Incinerator Dimension (Outter ) : L0.47 x W0.32 x H1.67 m
1 Unit Burner : 1st Burner 5 – 10 liter / hour, Light Oil Burner
Chamber Temperature :  Chamber ±900°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)

Exaust Stack
  – Diameter : 4 inchi
  – Height : ± 2 m.from ground level
  – Coating : High Temp.Paint
Refractory Construction :
  – Fire Brick : Fire Brick SK 32
  – Castable : CAJ-12
Chamber Insulation
  – 1st Wall : Fire Brick, SK-32
  – 2nd Wall : Ceramic Fibre, 128 kg/m³
  – Bottom : Insulating Brick
Shell & Structure Material Chamber :
  – Shell Plate t.3 mm ,Mild Steel
  – Joint Flange t.10 mm
  – Burner Port t.8 mm
  – Structure UNP 80 &
  – Coating : Epoxy Paint
FDF Blower : Sentrifugal ,2500 CMH, 220/50,2800 rpm, 1 unit
Electric Power Requirement : 3 kW. 380 V. 3 PH
Fuel : Diesel Oil ( Solar ) & Consumption : Max.10 liter / hour
Fuel Tank :
  – Cap. 10 ltr
  – Material Tank : Mild Steel plate t. 3 mm
  – Level Control
  – Drain Port
Control System :
  – ELC
  – Temperature Control : Digital
  – Thermocouple : Type – K.
  – Limit Switch
Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 2 x 3 m


2. PORTABLE INCENERATOR

Incinerator Single BurnerCap. : 1 to 3.75 kg/jam (30 Kg/hari) with Scrubber or w/o Scrubber
Type of Waste : Laboratory Waste / Medical Waste
Portable Single Burner Incinerator without Burner 3.75 kg/hour
Portable Single Burner Incinerator without Burner with Scrubber
Operating time : 8 hour /day

Dimension :
Chamber Dimension : 35 x 35 x 41 cm
Chamber Volume : 0.017 m3 (3.75 kg/jam)
Incinerator Body dimension : LxWxH :50 x 50 x 60 cm

Burner : 4-6 liter /jam, Light Oil Burner 1 unit
Chamber Temperature : ± 600 to 800 Deg C
Chamber Pressure : Negatif

Exhaust Stack Dia 250/150 mm, height 2 m , with high temp coating

Refractory Construction :
For Bottom floor ; Fire Clay Brick and Fire Brick
For Shell Plate ; Ceramic Fiber and Fire Brick
For Roof, Burner Port, Door and Nozzle ; Castable

Body Construction :
For Bottom, Shell and Roof Material from Mild Steel thk 3mm
Joint Flange 10 mm thickness
Structure Material : Shape and Mild Steel
Coating : Epoxy Coating

Air Blower 2″, 220 Volt, 50/60 Hz, 150 Watt

Optional : Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt

Diesel Oil : Consumption : ± 4 liter / hour & Oil Tank Capacity : 40 Liter

Control System :
  – Electronic Control Panle
  – Temperature Control : Digital
  – Thermocouple : Type – K.

Power Requirement : 1.3 kW / 220 Volt / 1phase / 50Hz

Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 2 x 3 m


3. DOUBLE BURNER INCINERATOR

Incinerator Double BurnerSpecifications :
Type of Waste : Bulk Density :± 0.1 – 0.15 kg/m³
Incinerator Type : Domesti Waste / Medical Waste
Incinerator Capacity : 20 kg/hour Multiple Chamber
Operation Time : 8 hour/day

Chamber Volume :
– 1st Chamber : 0.5 m³
– Mixing Room : 0.1 m³
– Second Chamber : 0.2 m³
Incinerator Dimension (Outter) : L:1.50 X W:1.2 X H:1.6 m

Burner :
– 1st Burner : 5 – 10 liter / hour, Light Oil Burner, 1 unit
– 2nd Burner : 5 –10 liter / hour, Light Oil Burner, 1 unit
Motor 220V / 50 Hz/ 1 Phase: 150 Watt x 2 : 300 Watt

 

Chamber Temperature :
– 1st Chamber : 600 – 800°C
– 2nd Chamber : 800- 1000°C
Chamber Pressure : Negatif (Under Atmosferic Pressure)

Exaust Stack :
– Diameter : 350mm (1st Stack), Ø200 mm (2nd Stack)
– Height : ±8 m.from ground level
– Sampling Port Ø3”
– Coating : High Temp.Paint

Insulation and Refractory Construction Materials :
– Fire Brick : Fire Brick SK 34
– Castable : CAJ-14
– Ceramic Fibre, 128 kg/m³
– Rockwool,60 kg/m³
– Glaswool, 20 kg/m³
– Bottom : Insulating Brick

Shell & Structure Material Chamber :
– Shell Plate thickness 3 mm ,Mild Steel
– Joint Flange thickness 12 mm
– Burner Port thickness 6 mm
– Plenum Plate thickness 3 mm
– Structure UNP 80 & UNP 50
– Lifter thickness 12 mm
– Coating : Epoxy Paint

FDF Blower : Sentrifugal  3″, 370 Watt , 3000 rpm,  1 unit

Diesel Oil Fuel Consumption : average15 liter / hour

Fuel Tank :
– Tank Capacity  250 ltr
– Material Tank : Mild Steel plate t. 4 mm
– Level Control
– Drain Port

Water Scrubber : Pump, Piping with Water Tank
Maximum Capacity 190 liter/min
Electricity 220 Volt, 50 Hz, 1 Phase, 370 Watt

Power Requirement : 1,2 kW / 220 Volt / 1phase / 50Hz

Control System :
– ELC
– Temperature Control : Digital
– Thermocouple : Type – K.
– Limit Switch

Ash : 5 – 10 % waste weight
Ash Discharging : Manual
Feeding System : Manual
Warranty Term : Six month ( Service)
Operator Requirement : 1 Person
Area Requirement : 4 x 5 m

Emission Quality According to Government Regulation for the following :
– Smokeless
– CO < 100 mg/Nm3
– NO2 < 300 mg/Nm3
– Opacity < 10%


 

Contact

PT. Karya Mitra Mulia

Address :
Jln. Ring Road Utara No. 134 Taman Yasmin VI, Bogor, Indonesia

We are ready to help you!
e-Mail : k555777888@yahoo.com
Phone : 0821 2210 4377

Calender

October 2019
M T W T F S S
« Aug    
 123456
78910111213
14151617181920
21222324252627
28293031  

Visitors online – 0:
users –
guests –
bots –
The maximum number of visits was – 2016-07-12:
all visitors – 21349:
users – 9
guests – 21308
bots – 32
browser – IE 9.0